Sioux City Ford

Job Name: 
Sioux City Ford

Location:
Sioux City, IA

Monoxivent Representative: 
Air Side Components (Brian Hansen), Omaha, NE

Summary: 
Air Side Components partnered with CW Suter to provide a complete vehicle exhaust removal system at the dealership.

The job include 17 underfloor exhaust outlets with Series 3000 no-crush hose, along with 17 23827 tailpipe adapters. In addition to this a REFCO (Refuse Clean Out) was incorporated.  The fan was a Backward Incline BI-195 model for 5100 CFM at 4.5″ SP and 7.5-HP.